Mechanical ventilation with heat recovery, usually shortened to MVHR, comes up in almost every conversation we have about Passive House and deep retrofit. It is also the part of a low-energy home that people find hardest to picture. Here is a plain explanation of what it does, when it makes sense and what to look out for if you are considering it for a home in Leeds or anywhere in Yorkshire.
What MVHR actually does
An MVHR system runs quietly in the background all the time. It draws stale, humid air out of kitchens, bathrooms and utility rooms, and supplies fresh, filtered air from outside to bedrooms and living spaces.
Both airflows pass through a heat exchanger inside the unit without mixing. Warmth from the outgoing air is passed to the incoming air, so in winter the fresh air arrives already tempered rather than cold, as it would through an open window or a trickle vent.
- Extract: from wet rooms, where moisture and smells are produced
- Supply: to bedrooms, living rooms and studies
- Transfer: air moves between the two through hallways and the gaps under internal doors
- Boost: a higher setting for showers, cooking or a busy house
Why it matters in an airtight home
Older houses are ventilated largely by accident, through gaps around windows, floors, pipes and loft hatches. When we make a home properly airtight, those draughts go, and so does that uncontrolled supply of fresh air. Something has to replace it, or moisture and stale air build up.
MVHR does that job without throwing the heat away, which is why it is part of every certified Passive House and EnerPHit building. At Bebington, our Passive House Plus home in Weetwood, the MVHR system works alongside an airtightness result of 0.42 air changes per hour.

What the Passive House standard asks of the unit
Not every MVHR unit performs the same. The Passive House Institute certifies ventilation units against a set of criteria for the cool, temperate climate that covers the UK. A certified unit has to show:
- A heat recovery rate of at least 75%
- Electricity use of no more than 0.45 Wh for each cubic metre of air it moves
- Air leakage within the unit below 3%
- Supply air of at least 16.5°C when it is -10°C outside, so the incoming air never feels cold
Certified units are listed in the Passive House Institute's component database, and choosing one is a sensible starting point. But the unit is only part of the system. How the ducts are designed, installed and set up matters just as much.
MVHR in new builds and retrofits
New builds
In a new build, MVHR is straightforward if it is planned early. The unit needs a home, often a plant cupboard, utility room or loft, and the ducts need clear routes through floors and ceilings that do not clash with steels, joists or drainage. Worked out at the design stage, that is simple. Squeezed in late, it means boxing in and compromises.
Retrofits
In an existing house it takes more thought, but it is often possible. At Oak Road, our conservation area retrofit in North Leeds, much of the MVHR ductwork went in while the floors and ceilings were open, which is the right moment to do it.
It is not always part of the plan. On our Headingley whole-house retrofit there is no MVHR, and the effort went into fabric, airtight detailing and windows instead. A long-standing rule of thumb said MVHR only suits very airtight homes, but a Passivhaus Trust research report found the evidence behind that rule was out of date and concluded that MVHR improves ventilation and lowers carbon emissions at all levels of airtightness. Whether it is right for your home depends on how far the rest of the retrofit goes and whether there is room for the unit and ducts.
What to ask before you fit one
- Who is designing it? Airflows should be calculated room by room, not guessed.
- Where will the unit go? Ideally inside the insulated part of the house, and somewhere you can easily reach to change filters.
- How will it be commissioned? Each room's airflow should be set and checked once the build is finished and clean.
- Will it be quiet? Duct sizing and silencers keep noise down, especially in bedrooms.
- What happens in summer? Many units have a summer bypass so cooler night air is not warmed on its way in.
Living with MVHR
Day to day there is very little to do. The main job is changing the filters, which the Passivhaus Trust's maintenance guidance says is typically needed every three to six months, depending on the manufacturer and how dusty the area is. It also recommends a full service by a specialist every four to five years.
You can still open the windows whenever you like. The difference is that you no longer have to for the house to stay fresh.
Thinking about MVHR for your home?
If you are planning a new build, an extension or a deep retrofit in Leeds or across Yorkshire and want to know whether MVHR makes sense, get in touch. These decisions are easiest to get right early, with drawings on the table. You can also read more about our Passive House work in Leeds.